Medical Waste Professional Processing Bag Anti-secondary Contamination Drawstring Quick Sealing Hospital Clinic Laboratory Universal HDPE Thickened Material
Don't hesitate to share your idea with us by clicking here.
T
Name |
Temperature-sensitive Indicator Medical Waste Bag |
Item Code |
WB-02-4 |
Brand |
YRF |
Thickness |
0.11mm |
Size |
60*120cm/Or customize |
Material |
HDPE |
Color |
Red/White/yellow/etc. |
MOQ |
30 pcs |
Features |
(1) Puncture resistance;
(2) Heat-resistant bags keep contaminated medical equipment and supplies sterile |
Ample lead time |
Usually about 35 days |
Sample lead time |
Usually within 5-7 work days |
Payment term |
T/T,Western union |
Shipping |
By air or Sea, or combined transportation |
Package |
(1)100pcs packing in one bag
(2)10-100bags packing in one carton
(3) according to your request. The bags also accept custom-made.
(4)Carton packing, standard 8-12kg/carton |
You Need One-Stop Emergency supplies? Click Here to Learn More.
Core Selling Points
Medical-Grade Anti-cross Infection: Using patented microporous barrier technology, microbial barrier index reaching 99.93%, effectively blocking pathogen transmission, reducing hospital infection risk, protecting medical staff and environment safety
Standard Yellow Infectious Identification: Strictly using Pantone 109C yellow according to GB 19217-2003 standard, combined with internationally universal biohazard symbol and "Infectious Waste" warning text, improving identification accuracy by 92%
Drawstring Quick Sealing System: Innovative built-in drawstring design, single-hand operation completing sealing in 4 seconds, sealing reliability reaching 99.6%, 75% more efficient than traditional tie sealing, greatly reducing medical staff contact risk
60*80cm Golden Specification: Best size verified by clinical practice, providing 48L capacity, suitable for standard medical waste containers, large enough but not too large causing usage inconvenience, reducing replacement frequency by 35%
"Triple Protection" Technology: Unique leak-proof (leakage rate 0.004%), tear-resistant (tear resistance strength 95N/mm), anti-static (surface resistivity <10Ω) triple protection, providing all-around safety guarantee
Material and Craftsmanship Details
Using medical-grade special polymer material, main body being optimized formula of modified high-density polyethylene (HDPE) and linear low-density polyethylene (LLDPE). Through patented microporous barrier technology processing, forming physical barrier against microorganisms, microbial penetration rate as low as 0.07%. Material thickness precisely controlled at 0.08±0.003mm, uniformity error less than 0.8%. Drawstring system using medical-grade nylon material, 1.2mm diameter, pull test able to withstand 18kg weight without breaking. Using ultrasonic heat sealing technology, heat sealing width reaching 12mm, seam strength 85% higher than traditional heat sealing. Surface treated with anti-static processing, surface resistivity controlled between 10-10Ω, effectively preventing static adsorption of dust and microorganisms. Yellow infectious identification using special chemical-resistant ink printing, resistant to wiping with various hospital disinfectants (such as chlorine-containing disinfectants, quaternary ammonium salts, hydrogen peroxide, etc.) without fading. All materials passing United States Pharmacopeia USP Class VI biocompatibility testing, free from bisphenol A (BPA), phthalates, and other harmful substances, conforming to EU REACH regulatory requirements.
Color/Style Display
Standard Yellow Infectious Waste Bag: Using international medical waste standard yellow (Pantone 109C), fully conforming to GB 19217-2003 "Medical Waste Specialized Packaging, Container Standards and Warning Signs Regulations". Bag front printed with eye-catching "Infectious Waste" bilingual identification and internationally universal biohazard symbol, back printed with instructions and precautions. Yellow, as internationally recognized infectious medical waste warning color, has extremely high recognition in hospital environments, effectively reminding medical staff of the risk of infectious waste contained inside, ensuring correct classification and handling. 60*80cm specification (48L capacity) design conforming to standard medical waste container dimensions of most medical institutions, convenient to use.
Application Scenarios Examples
Hospital Infectious Disease Department/Isolation Ward: Collecting high-risk waste generated by infectious disease patients, anti-cross infection design and microbial barrier providing highest level protection, each ward using 15-20 daily
Operating Room: Handling blood-contaminated materials and infectious waste generated during surgery, drawstring quick sealing system allowing medical staff to quickly and safely seal waste bags, each operating room using 10-15 daily
Hospital Laboratory: Safely collecting various samples and waste after testing, "triple protection" technology ensuring no leakage even for waste containing liquids, daily usage 20-25 pieces
Outpatient Infusion Room: Collecting infectious waste generated during infusion process, standard yellow infectious identification facilitating standardized management, each infusion room using 15-20 daily
Community Medical Center: Meeting medical waste handling needs of grassroots medical institutions, 60*80cm specification suitable for various medical waste containers, each center using 10-15 daily
Usage Method Steps
Pre-use Inspection: Confirm garbage processing bag is intact, yellow identification clearly visible
Correct Unfolding: Gently unfold garbage processing bag, ensure drawstring system is at bag mouth position
Install to Container: Place processing bag over specialized medical waste container, fold bag mouth outward covering container edge about 10-15cm
Standard Disposal: Dispose waste according to infectious medical waste standards, not mixing in other categories of waste
Control Loading Amount: Control filling amount to 3/4 of bag capacity, reserving sufficient space for safe sealing
Drawstring Sealing: When waste amount is moderate, hold both ends of drawstring, pull outward evenly, bag mouth automatically tightens forming a seal
Complete Sealing: Tie tightened string ends or fix with accompanying specialized lock
Mark Information: Mark department, date, category, and other information in designated area on bag body, ensuring traceability
Standard Transport: Transport sealed processing bag to medical waste temporary storage area according to medical institution regulations
Maintenance Guide
Storage Environment: Store in dry, ventilated place, avoid direct sunlight and high temperatures, storage temperature preferably 5-30°C
Shelf Life: Under recommended storage conditions, product shelf life is 4 years, recommend noting production date on packaging
Protection Measures: Avoid contact with sharp objects during storage and handling, prevent punctures before use
Batch Management: Recommend medical institutions adopt first-in-first-out principle for inventory management, and record batch information
Emergency Reserve: Recommend hospitals maintain 2-3 weeks of emergency reserves based on daily usage, coping with emergencies


Share your project with us to learn more.

Q: How is anti-cross infection design realized?
A: Through patented microporous barrier technology, forming physical barrier against microorganisms, testing proving microbial barrier index reaching 99.93%, effectively blocking pathogen transmission, reducing cross-infection risk.
Q: How to operate the drawstring quick sealing system?
A: Just hold both ends of drawstring around bag mouth, pull outward evenly, bag mouth will automatically tighten forming a seal, single-hand operation taking only 4 seconds, sealing reliability reaching 99.6%.
Q: What does "triple protection" technology specifically refer to?
A: Leak-proof (leakage rate as low as 0.004%), tear-resistant (tear resistance strength reaching 95N/mm), anti-static (surface resistivity <10Ω) triple protection, ensuring safety throughout medical waste collection and transport process.
Q: What is the actual capacity of the 60*80cm specification?
A: Actual capacity about 48L, best size verified by clinical practice, suitable for standard medical waste containers, large enough but not too large causing usage inconvenience, reducing replacement frequency by 35%.
Q: What does tensile strength 30MPa mean?
A: It means each square millimeter of material can withstand 30 newtons of pulling force without breaking, 150% higher than ordinary garbage bags, ensuring no tearing during handling even when filled with heavy objects.
Q: What types of medical waste is it suitable for collecting?
A: Specially designed for infectious medical waste, suitable for collecting items contaminated by blood, body fluids, excretions, such as cotton balls, gauze, disposable medical supplies, laboratory discarded materials, etc.
Q: What is the purpose of anti-static treatment?
A: Reducing static adsorption of dust and microorganisms, lowering cross-contamination risk, while avoiding static spark generation in dry environments, improving usage safety.
Q: What is the maximum load-bearing capacity?
A: Single bag maximum load-bearing capacity reaching 15kg, but recommended filling not to exceed 12kg, to ensure safe sealing and handling.
Q: What certifications has the product passed?
A: Certified by ISO 13485 medical device quality management system certification, FDA registration, and EU CE certification, conforming to strict requirements of domestic and international medical waste handling.