Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Thermal Protection: | A |
| Standard: | Standard Ga10-2014 Certification |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Name | 800°C Heat-resistant Firefighting Suit Set | Item Code | SAB-47-1 |
| Brand | YRF | TColor | Deep Blue/Orange-red/orange |
| Material | moisture resistant fabric | Size | Universal size |
| Accessories include | top/ bottom trousers/belt /helmet/gloves/shoes | MOQ | 30 pcs |
| Features | The Forest Firefighting Suit multi-layer composite structure provides all-around protection, with TPP thermal protection value of 28CAL/AM2, and hydrostatic pressure resistance >50KPA, With tear resistance up to 38N. | ||
| Ample lead time | Usually about 35 days | ||
| Sample lead time | Usually within 5-7 work days | ||
| Payment term | T/T,Western union | ||
| Shipping | By air or Sea, or combined transportation | ||
| Package | 1 pc/polybag, accept custom package | ||


Application Scenarios Examples
Building Fire Rescue: Facing high-rise building fires, the firefighting suit's 800°C heat resistance and 28CAL/AM2
thermal protection value ensure firefighters can safely approach fire sources. The multi-layer protection structure
resists high-temperature radiation and spark invasion. The waterproof design keeps firefighters dry when using fire
hoses. The reflective strip design maintains team visual contact in dense smoke. The professional protection design
extends firefighters' effective working time in high-temperature environments by an average of 18 minutes,
significantly improving rescue success rates.
Forest Fire Fighting: Forest fire environments are complex and variable. The firefighting suit's lightweight design
5.2KG reduces the burden of long-distance walking. The breathable structure >4500G/M²·24H reduces heat stress
risks. The heat-resistant material withstands high temperatures generated by burning trees. The tear-resistant
characteristic 38N prevents tearing by branches. The reflective design maintains team contact in dense smoke.
Actual combat data shows this equipment improves action efficiency by 25% in forest fires and reduces heat
stress risks by 40%.
Industrial Fire Handling: Industrial fires are often accompanied by chemical substances and metal burning, producing
extremely high temperatures and toxic smoke. The firefighting suit's multi-layer protection system simultaneously
addresses high temperatures and chemical substances. The hydrostatic pressure resistance >50KPA)ensures
chemical liquids don't penetrate. The reflective design maintains direction sense in complex plants. The 72-hour
continuous work support ensures completion of long-duration rescue tasks in large industrial fires, without interruption
due to equipment limitations.
Post-earthquake Rescue: Earthquakes are often accompanied by secondary fires, with rescue environments including
collapsed buildings and open flames. The firefighting suit's tear-resistant design 38N prevents cutting by sharp objects
in rubble. The heat resistance addresses sudden fire situations. The lightweight design supports long-duration search
and rescue. The waterproof function maintains dryness in rain and snow. The reflective design improves safety in night
rescue. Statistics show that rescue teams using this equipment experience 35% less efficiency decline in 72-hour
continuous operations compared to traditional equipment.

Usage Method Steps
Pre-use Inspection: Thoroughly check the integrity of all firefighting suit components, confirming no damage,
aging, or functional abnormalities, paying special attention to reflective strips, seams, and protective layer status.
Base Layer Dressing: Put on specialized flame-retardant underwear, ensuring dryness and comfort, enhancing
sweat absorption and basic heat insulation.
Main Equipment Dressing: First put on firefighting pants and secure the belt, then put on the firefighting jacket
and fully close the zipper, ensuring tight connection between upper and lower parts with no gaps.
Additional Equipment Installation: Install professional equipment such as self-contained breathing apparatus
based on task requirements, adjusting the fastening system to ensure stability and comfort.
Protective Accessories Wearing: Sequentially put on professional boots and gloves, finally wearing the helmet
and adjusting the face shield to the optimal protective position.
Final Safety Confirmation: Conduct full-body movement tests, confirming all protective equipment is in place,
communication equipment is working normally, and team equipment cross-checking is complete.
Maintenance Guide:
Post-use Inspection: Thoroughly check for damage, deformation, or functional abnormalities in all components,
paying special attention to the material condition of areas experiencing high temperatures
Professional Cleaning Requirements: Use professional firefighting suit cleaning agents, avoiding ordinary
detergents that may damage flame retardance, water temperature not exceeding 40°C, following temperature and
procedure requirements
Regular Decontamination Treatment: Choose professional decontamination methods based on contaminant type,
ensuring no impact on material performance and protective effects
Complete Drying Storage: Must be completely dried before storage after cleaning, hanging in ventilated areas,
avoiding folded storage causing material damage
Regular Professional Testing: Conduct comprehensive professional testing quarterly, evaluating flame retardance,
physical strength, and the status of various functional systems
Share your project with us to learn more.

Q: How high a temperature environment can this firefighting suit set withstand?
A: This firefighting suit set has heat resistance up to 800°C, with thermal protection value TPP reaching 28CAL/AM2, providing reliable protection for firefighters in extreme high-temperature environments.
Q: Will the firefighting suit set affect firefighters' mobility?
A: Although providing comprehensive protection, the firefighting suit set uses dynamic cutting technology and a balanced weight design of 5.2KG, ensuring firefighters maintain good mobility in complex fire scene environments.
Q: How does the firefighting suit set address heat stress issues?
A: The internal breathable design gives vapor transmission rate >4500G/M²·24H, effectively managing internal heat and moisture, reducing heat stress reactions, extending effective working time.
Q: What scenarios are suitable for different colors of firefighting suit sets?
A: Model 87 red is suitable for standard fire brigades; Model 02 black with yellow-green reflective strips is suitable for industrial fire brigades; Model 14 black with bright yellow reflective strips is suitable for night and low-visibility environment rescue.
Q: How is the waterproof performance of the firefighting suit set?
A: The firefighting suit set has hydrostatic pressure resistance >50KPA, effectively resisting water flow impact and long-duration wetting, ensuring dryness when using fire hoses and foam extinguishing agents.
Q: How long is the service life of the firefighting suit set?
A: Under normal use and maintenance conditions, the firefighting suit set can be used for 3-5 years, but professional evaluation is recommended annually to ensure no degradation of key protective properties.
Q: How is the tear resistance of the firefighting suit set?
A: The firefighting suit set has tear resistance up to 38N, effectively resisting physical damage in extreme environments such as building collapses and explosions, providing reliable structural integrity