Hospital Specialized Medical Waste Bag HDPE High-Density Material Leak-proof Puncture-resistant Yellow Infectious Waste Collection Bag 60×80cm
Our Main Products
Don't hesitate to share your idea with us by clicking here.
Product Description
This hospital specialized medical waste bag is made of medical-grade HDPE (High-Density Polyethylene) material, with 60×80cm size design conforming to the Medical Waste Management Regulations standard requirements.Through third-party testing, the leak-proof rate reaches 99.8%, and puncture resistance strength reaches 350g,effectively preventing sharp objects penetration and liquid leakage. The yellow design strictly follows GB 19217-2003 medical waste specialized marking specifications, with prominent "Infectious Waste" warning identification improving medical
waste classification accuracy by 85%. Material thickness is 0.08mm, with load-bearing capacity of 8kg, meeting hospital daily infectious waste collection needs. Using double-track heat sealing technology, sealing strength improved by 60%, ensuring medical waste transportation safety.
| Name |
HDPE High-Density Material Garbage Bag |
Item Code |
WB-05-1 |
| Brand |
YRF |
Thickness |
1.35 Mil |
| Size |
61*81CM |
Material |
HDPE |
| Color |
Red/White/yellow/etc. |
MOQ |
100 Volume |
| Features |
(1) Puncture resistance; (2) Heat-resistant bags keep contaminated medical equipment and supplies sterile |
| Ample lead time |
Usually about 35 days |
| Sample lead time |
Usually within 5-7 work days |
| Payment term |
T/T,Western union |
| Shipping |
By air or Sea, or combined transportation |
| Package |
(1)100pcs packing in one bag (2)10-100bags packing in one carton (3) according to your request. The bags also accept custom-made. (4)Carton packing, standard 8-12kg/carton |
You Need One-Stop Emergency supplies? Click Here to Learn More.
Application Scenarios Examples
Hospital Infectious Disease Department: Collecting used gauze, cotton balls, disposable medical supplies, and other infectious waste from patients, yellow identification facilitating quick recognition, leak-proof design ensuring departmental environment safety, daily usage 20-30 pieces
Hospital Laboratory: Safely collecting waste after blood and body fluid sample testing, HDPE material effectively preventing puncture by sharp objects and broken test tubes, ensuring laboratory staff safety, daily usage 30-40 pieces
Outpatient Infusion Room: Collecting discarded infusion bags, syringes, and other infectious waste, 60×80cm size suitable for standard medical waste bins, convenient for nurses to process centrally, daily usage 15-25 pieces
Operating Room: Collecting blood-stained dressings, disposable surgical supplies, and other items generated during surgery, leak-proof characteristics ensuring blood doesn't spill, maintaining operating room environment safety, average usage 2-3 pieces per surgery
Hospital Wards: Collecting waste generated by patients, especially personal items of infectious disease patients, double- track heat sealing ensuring safe sealing, reducing nosocomial infection risk, daily usage 1-2 pieces per bed
Material and Craftsmanship Details
Using medical-grade high-density polyethylene (HDPE) raw material, with special additives enhancing material toughness, thickness uniformly controlled at 0.08±0.005mm. Material undergoes anti-puncture treatment, able to resist 350g standard sharp object puncture test. Overall using seamless integrated extrusion process, avoiding weak connection points. Yellow warning identification uses environmentally friendly non-toxic printing process, conforming to European Union EN 71-3 standard, safe for contact with medical environments. Bottom uses star- shaped heat sealing technology, improving load-bearing uniformity. Material passes biological safety assessment, free from phthalates, heavy metals, and other harmful substances, conforming to medical device auxiliary material safety requirements.
Core Selling Points
Medical-grade HDPE Material: Using high-density polyethylene (HDPE) material, with tighter molecular arrangement, tensile strength increased by 65%, effectively preventing puncture by sharp objects during collection
99.8% Leak-proof Technology: Through third-party authoritative testing, leak-proof rate reaches 99.8%, effectively preventing leakage of infectious liquids like blood and body fluids, reducing hospital infection risk
Standardized Yellow Identification: Strictly complying with GB 19217-2003 "Medical Waste Specialized Packaging, Container Standards and Warning Signs Regulations", yellow warning color combined with "Infectious Waste" identification, improving classification accuracy by 85%
Double-track Heat Sealing: Using double-track heat sealing technology, sealing strength improved by 60% compared to ordinary heat sealing, effectively preventing waste scattering during transportation
60×80cm Practical Size: Designed based on clinical application data analysis for optimal size, suitable for daily infectious waste collection in various hospital departments, still easy to tie and seal when filled
Usage Method Steps
Preparation: Check if medical waste bag is intact, confirm yellow identification is clearly visible
Correct Placement: Place waste bag over specialized medical waste bin, fold bag mouth outward covering bin edge, ensure bag body fully expanded
Waste Disposal: According to medical waste classification standards, place infectious waste into bag, filling no more than 3/4 of bag capacity
Safe Sealing: Carefully remove waste bag, avoiding contents spillage, twist bag mouth then knot or use specialized
tie for sealing
Identification Confirmation: Ensure "Infectious Waste" identification on bag is intact and visible, add department, date, and other additional information if necessary Standardized Transport: Transport sealed waste bag to medical waste temporary storage area according to hospital regulations, avoid staying in public areas
Maintenance Guide
Storage Conditions: Store in dry, ventilated place, avoid direct sunlight, storage temperature should remain between -10°C and 50°C
Usage Period: Unopened product can be stored for 3 years, recommend checking packaging integrity and product
toughness before use
Batch Management: Recommend hospitals adopt first-in-first-out principle for inventory management, ensuring use of latest production batches
Environmental Requirements: Recommended usage environment temperature between 0°C and 40°C, extreme temperatures may affect material performance
Precautions: Avoid direct contact with sharp objects, check waste bag for damage before use, immediately replace if damage found


Color/Style Display
Yellow: Standard medical waste warning yellow (Pantone 109C), conforming to the color specification requirements for infectious waste in the national Medical Waste Classification Catalog. Yellow and black warning identification form a sharp contrast, easily identifiable in hospital environments, improving waste classification accuracy. Standardized yellow design helps medical staff quickly distinguish different categories of medical waste, standardizing hospital infectious waste management.


Share your project with us to learn more.
FAQ

Q: What is the difference between this medical waste bag material and ordinary plastic bags?
A: Uses medical-grade HDPE high-density polyethylene material, with tighter molecular arrangement, 65% higher tensile strength, puncture resistance reaching 350g, far superior to ordinary plastic bags.
Q: Why must yellow bags be used to collect infectious waste?
A: Yellow is the specialized color for infectious waste specified by national GB 19217-2003 standard, facilitating quick identification by medical staff, improving classification accuracy, ensuring safe handling of medical waste.
Q: How is leak-proof performance guaranteed?
A: Through seamless integrated extrusion process and double-track heat sealing technology, third-party tested leak-proof rate reaches 99.8%, effectively preventing liquid leakage.
Q: What types of medical waste is it suitable for collecting?
A: Suitable for collecting infectious waste, including items contaminated by patient blood, body fluids, excretions, such as cotton balls, gauze, disposable medical supplies, etc.
Q: What scenarios is the 60×80cm size suitable for?
A: This size is suitable for standard medical waste bins, applicable for daily infectious waste collection in various hospital departments, meeting load-bearing requirements for about 8kg of waste.
Q: How to determine if product quality is acceptable?
A: Observe if material is uniform, without bubbles and weak points; check if heat sealing is firm; see if identification printing is clear; test if toughness is good, not easily torn.
Q: What should be noted during use?
A: Do not exceed 3/4 capacity; avoid putting in sharp items that might directly puncture; when sealing, twist bag mouth and knot securely; ensure identification is visible facing outward.
Q: How to correctly handle waste bags after they're filled?
A: Twist bag mouth and knot or seal with tie, ensuring no leakage; transport to medical waste temporary storage area according to hospital regulations; avoid staying in public areas for long periods.
Q: Does it contain substances harmful to humans?
A: Does not contain phthalates, heavy metals, or other harmful substances, passes biological safety assessment, conforming to medical device auxiliary material safety requirements.